STANDARDS OF PRACTICE
OF
THE AMERICAN SOCIETY OF
HOME INSPECTORS
Introduction
Purpose and Scope
Limitations and Exclusions
Structural
Exterior
Roofing
Plumbing
Electrical
Heating
Air conditioning
Interiors
Insulation and Ventilation
Glossary
1.1 The American Society of Home Inspectors®, Inc.
A.
The American Society of Home Inspectors, Inc. (ASHI®) is a
not-for-profit professional society established in 1976 whose
volunteer membership consists of private, fee-paid home inspectors.
ASHI's objectives include promotion of excellence within the
profession and continual improvement of its members' inspection
services to the public.
1.2 These Standards of Practice
A. provide inspection
guidelines
B. make public the services provided by private
fee-paid inspectors
C. define certain terms relating to
these inspections
2.1 Inspections performed to these Standards shall:
A.
provide the client with a better understanding of the property
conditions, as observed at the time of the inspection
2.2 Inspectors shall:
A. observe readily
accessible installed systems and components listed in these
Standards
B. submit a written report to the client which
shall:
- describe those components specified to be described in
sections 4-12 of these Standards
- state which systems and components designated for
inspection in these Standards have been inspected
- state any systems and components so inspected which
were found to be in need of immediate major repair
2.3 These Standards are not intended to limit inspectors
from:
A. reporting observations and conditions in addition to
those required in Section 2.2
B. excluding systems and
components from the inspection if requested by the client
3 GENERAL
LIMITATIONS AND EXCLUSIONS
Back
to Top
3.1 General limitations:
A. Inspections done in
accordance with these Standards are visual and are not
technically exhaustive.
B. These Standards are applicable
to buildings with four or less dwelling units and their garages or
carports.
3.2 General exclusions:
A. Inspectors are NOT
required to report on:
- life expectancy of any component or system
- the causes of the need for a major repair
- the methods, materials and costs of corrections
- the suitability of the property for any specialized use
- compliance or non-compliance with applicable regulatory
requirements
- the market value of the property or its marketability
- the advisability or inadvisability of purchase of the property
- any component or system which was not observed
- the presence or absence of pests such as wood damaging
organisms, rodents, or insects
- cosmetic items, underground items, or items not permanently
installed
B. Inspectors are NOT required to:
- offer or perform any act or service contrary to law
- offer warranties or guarantees of any kind
- offer or perform engineering, architectural, plumbing,
or any other job function requiring an occupational license
in the jurisdiction where the inspection is taking place, unless
the inspector holds a valid occupational license, in which case
he/she may inform the client that he/she is so licensed, and is
therefore qualified to go beyond the ASHI® Standards of Practice,
and for an additional fee, perform additional inspections beyond
those within the scope of the basic ASHI® inspection
- calculate the strength, adequacy, or efficiency of any
system or component
- enter any area or perform any procedure which may damage the
property or its components or be dangerous to the
inspector or other persons
- operate any system or component which is shut down
or otherwise inoperable
- operate any system or component which does not respond to
normal operating controls
- disturb insulation, move personal items, furniture, equipment,
plant life, soil, snow, ice, or debris which obstructs access or
visibility
- determine the presence or absence of any suspected hazardous
substance including but not limited to toxins, carcinogens, noise,
contaminants in soil, water, and air
- determine the effectiveness of any system installed to
control or remove suspected hazardous substances
- predict future conditions, including but not limited to
failure of components
- project operating costs of components
- evaluate acoustical characteristics of any system or
component
3.3 Limitations and exclusions specific to individual
systems are listed in the following sections.
Back To Top
4 SYSTEM: STRUCTURAL COMPONENTS
4.1 The inspector shall observe:
A.
structural components including:
- foundation
- floors
- walls
- columns
- ceilings
- roofs
4.2 The inspector shall:
A. describe the
type of:
- foundation
- floor structure
- wall structure
- columns
- ceiling structure
- roof structure
B. probe structural components where deterioration is
suspected. However, probing is NOT required when probing would
damage any finished surface
C. enter under floor crawl spaces
and attic spaces except when access is obstructed, when entry
could damage the property, or when dangerous or adverse
situations are suspected
D. report the methods used to
observe under floor crawl spaces and attics
E. report
signs of water penetration into the building or signs of abnormal or
harmful condensation on building components
5.1 The inspector shall observe:
A. wall
cladding, flashings and trim
B. entryway doors and
representative number of windows
C. garage door
operators
D. decks, balconies, stoops, steps, areaways, and
porches including railings
E. eaves, soffits and fascias
F.
vegetation, grading, drainage, driveways, patios, walkways and
retaining walls with respect to their effect on the condition of the
building
5.2 The inspector shall:
A. describe wall
cladding materials
B. operate all entryway doors and
representative number of windows including garage doors,
manually or by using permanently installed controls of any
garage door operator
C. report whether or not any garage door
operator will automatically reverse or stop when meeting reasonable
resistance during closing
5.3 The inspector is NOT required to
observe:
A. storm windows, storm doors, screening,
shutters, awnings and similar seasonal accessories
B.
fences
C. safety glazing
D. garage door operator remote
control transmitters
E. geological conditions
F. soil
conditions
G. recreational facilities
H. outbuildings other
than garages and carports
6.1 The inspector shall observe:
A. roof
coverings
B. roof drainage systems
C. flashings
D.
skylights, chimneys and roof penetrations
E. signs of leaks or
abnormal condensation on building components
6.2 The inspector shall:
A. describe the
type of roof covering materials
B. report the methods used to
observe the roofing
6.3 The inspector is NOT required to:
A. walk on
the roofing
B. observe attached accessories including but
not limited to solar systems, antennae, and lightning arrestors
Back To Top
7.1 The inspector shall observe:
A. interior
water supply and distribution system including:
- piping materials, including supports and insulation
- fixtures and faucets
- functional flow
- leaks
- cross connections
B. interior drain, waste and vent system, including:
- traps; drain, waste, and vent piping; piping supports and pipe
insulation
- leaks
- functional drainage
C. hot water systems including:
- water heating equipment
- normal operating controls
- automatic safety controls
- chimneys, flues, and vents.
D. fuel storage and distribution systems including:
- interior fuel storage equipment, supply piping, venting, and
supports
- leaks
E. sump pump
7.2 The inspector shall:
A. describe:
- water supply and distribution piping materials
- drain, waste, and vent piping materials
- water heating equipment
B. operate all plumbing fixtures, including their faucets
and all exterior faucets attached to the house
7.3 The inspector is NOT required to:
A. state
the effectiveness of anti-siphon devices
B. determine whether
water supply and waste disposal systems are public or
private
C. operate automatic safety controls
D. operate
any valve except water closet flush valves, fixture faucets, and
hose faucets
E. observe:
- water conditioning systems
- fire and lawn sprinkler systems
- on-site water supply quantity and quality
- on-site waste disposal systems
- foundation irrigation systems
- spas, except as to functional flow and functional
drainage
Back To Top
8.1 The inspector shall observe:
A. service entrance
conductors
B. service equipment, grounding equipment, main
overcurrent device, main and distribution panels
C. amperage and
voltage ratings of the service
D. branch circuit conductors,
their overcurrent devices, and the compatibility of their ampacities
and voltages
E. the operation of a representative number of
installed lighting fixtures, switches and receptacles located
inside the house, garage, and on its exterior walls
F. the
polarity and grounding of all receptacles within six feet of
interior plumbing fixtures, and all receptacles in the garage or
carport, and on the exterior of inspected structures
G. the
operation of Ground Fault Circuit Interrupters
8.2 The inspector shall:
A. describe:
- service amperage and voltage
- service entry conductor materials
- service type as being overhead or underground
- location of main and distribution panels
B. report any observed aluminum branch circuit wiring
8.3 The inspector is NOT required to:
A. insert
any tool, probe, or testing device inside the panels
B. test or
operate any overcurrent device except Ground Fault Circuit
Interrupters
C. dismantle any electrical device or control
other than to remove the covers of the main and auxiliary
distribution panels
D. observe
- low voltage systems
- smoke detectors
- telephone, security, cable TV, intercoms, or other ancillary
wiring that is not a part of the primary electrical distribution
system
Back To Top
9.1 The inspector shall observe:
A. permanently
installed heating systems including:
- heating equipment
- normal operating controls
- automatic safety controls
- chimneys, flues, and vents
- solid fuel heating devices
- heat distribution systems including fans, pumps, ducts
and piping, with supports, dampers, insulation, air filters,
registers, radiators, fan coil units, convectors
- the presence of an installed heat source in each room
9.2 The inspector shall:
A. describe:
- energy source
- heating equipment and distribution type
B. operate the systems using normal operating controls
C. open
readily openable access panels provided by the manufacturer
or installer for routine homeowner maintenance
9.3 The inspector is NOT required to:
A.
operate heating systems when weather conditions or other
circumstances may cause equipment damage
B. operate automatic
safety controls
C. ignite or extinguish solid fuel
fires
D. observe:
- the interior of flues
- fireplace insert flue connections
- humidifiers
- electronic air filters
- the uniformity or adequacy of heat supply to the various rooms
10 SYSTEM: CENTRAL AIR CONDITIONING
10.1 The inspector shall observe:
A. central
air conditioning including:
- cooling and air handling equipment
- normal operating controls
B. distribution systems including:
- fans, pumps, ducts and piping, with supports, dampers,
insulation, air filters, registers, fan-coil units
- the presence of an installed cooling source in each room
10.2 The inspector shall:
A. describe:
- energy sources
- cooling equipment type
B. operate the systems using normal operating controls
C. open
readily openable access panels provided by the manufacturer
or installer for routine homeowner maintenance
10.3 The inspector is NOT required to:
A.
operate cooling systems when weather conditions or other
circumstances may cause equipment damage
B. observe non
-central air conditioners
C. observe the uniformity or
adequacy of cool-air supply to the various rooms
11.1 The inspector shall observe:
A. walls, ceiling,
and floors
B. steps, stairways, balconies, and railings
C.
counters and a representative number of cabinets
D. a
representative number of doors and windows
E. separation walls,
ceilings, and doors between a dwelling unit and an attached garage
or another dwelling unit
F. sumps
11.2 The inspector shall:
A. operate a
representative number of primary windows and interior doors
B.
report signs of water penetration into the building or signs of
abnormal or harmful condensation on building components
11.3 The inspector is NOT required to
observe:
A. paint, wallpaper, and other finish
treatments on the interior walls, ceilings. and floors
B.
carpeting
C. draperies, blinds, or other window treatments
D.
household appliances
E. recreational facilities or another
dwelling unit
12 SYSTEM: INSULATION &
VENTILATION
12.1 The inspector shall observe:
A. insulation and
vapor retarders in unfinished spaces
B. ventilation of attics and
foundation areas
C. kitchen, bathroom, and laundry venting
systems
12.2 The inspector shall describe:
A. insulation and
vapor retarders in unfinished spaces
B. absence of same in
unfinished space at conditioned surfaces
12.3 The inspector is NOT required to report
on:
A. concealed insulation and vapor retarders
B. venting
equipment which is integral with household appliances
Back
to Top
GLOSSARY
Automatic Safety Controls:
Devices designed and
installed to protect systems and components from excessively high or
low pressures and temperatures, excessive electrical current, loss
of water, loss of ignition, fuel leaks, fire, freezing, or other
unsafe conditions.
Central Air Conditioning:
A system which uses ducts to
distribute cooled and/or dehumidified air to more than one room or
uses pipes to distribute chilled water to -heat exchangers in more
than one room, and which is not plugged into an electrical
convenience outlet.
Component:
A readily accessible and observable aspect
of a system, Such as a floor, or wall, but not individual pieces
such as boards or nails where many similar pieces make up the
component.
Cross Connection:
Any physical connection or
arrangement between potable water and any source of
contamination.
Dangerous or Adverse Situations:
Situations which pose
a threat of injury to the inspector, and those situations which
require the use of special protective clothing or safety
equipment.
Describe:
Report in writing a system or component by
its type, or other observed characteristics, to distinguish it from
other components used for the same purpose.
Dismantle:To take apart or remove any component, device or
piece of equipment that is bolted, screwed, or fastened by other
means and that would not be dismantled by a homeowner in the course
of normal household maintenance.
Engineering:
Analysis or design work requiring
extensive preparation and -experience in the use of mathematics,
chemistry, physics, and the engineering sciences.
Enter:
To go into an area to observe all visible
components.
Functional Drainage:
A drain is functional when it
empties in a reasonable amount of time and does not overflow when
another fixture is drained simultaneously.
Functional Flow:
A reasonable flow at the highest
fixture in a dwelling when another fixture is operated
simultaneously.
Household Appliances:
Kitchen and laundry appliances,
room air conditioners, and similar appliances
Inspector:
Any person who examines any component of a
building, through visual means and through normal user controls,
without the use of mathematical sciences.
Installed:
Attached or connected such that the
installed item requires tools for removal.
Normal Operating Controls:
Homeowner operated devices
such as a thermostat, wall switch, or safety switch.
Observe:
The act of making a visual examination.
On-site Water Supply Quality:
Water quality is based on
the bacterial, chemical, mineral, and solids content of the
water.
On-site Water Supply Quantity:
Water quantity is the
rate of flow of water.
Operate:
To cause systems or equipment to function.
Primary Windows and Doors:
Windows and/or exterior
doors which are designed to remain in their respective openings year
round and not left open for the entire summer.
Readily Openable Access Panel:
A panel provided for
homeowner inspection and maintenance which has removable or operable
fasteners or latch devices in order to be lifted off, swung open, or
otherwise removed by one person, and its edges and fasteners are not
painted in place. Limited to those panels within normal reach or
from a 4-foot stepladder, and which are not blocked by stored items,
furniture, or building components.
Recreational Facilities:
Spas, saunas, steam baths,
swimming pools, tennis courts, playground equipment, and other
exercise, entertainment, or athletic facilities.
Representative Number:
For multiple identical
components such as windows and electrical outlets - one such
component per room. For multiple identical exterior components - one
such component on each side of the building.
Roof Drainage Systems:
Gutters, downspouts, leaders,
splash blocks, and similar components used to carry water off a roof
and away from a building.
Safety Glazing:
Tempered glass, laminated glass, or
rigid plastic.
Shut Down:
A piece of equipment or a system is shut
down when it cannot be operated by the device or control which a
home owner should normally use to operate it. If its safety switch
or circuit breaker is in the "off' position, or its fuse is missing
or blown, the inspector is not required to reestablish the circuit
for the purpose of operating the equipment or system.
Solid Fuel Heating Device:
Any wood, coal, or other
similar organic fuel burning device, including but not limited to
fireplaces whether masonry or factory built, fireplace inserts and
stoves, wood stoves (room heaters), central furnaces, and
combinations of these devices.
Structural Component:
A component which supports
non-variable forces or weights (dead loads) and variable forces or
weights (live loads).
System:
A combination of interacting or interdependent
components, assembled to carry out one or more functions.
Technically Exhaustive:
An inspection is technically
exhaustive when it involves the extensive use of measurements,
instruments, testing, calculations, and other means to develop
scientific or engineering findings, conclusions, and
recommendations.
Under floor Crawl Space:
The area within the confines
of the foundation and between the ground and the underside of the
lowest floor structural component.
CODE OF ETHICS OF THE AMERICAN SOCIETY OF HOME INSPECTORS
Honesty, justice, and courtesy form a moral philosophy which,
associated with mutual interest among people, constitutes the
foundation of ethics. The members should recognize such a standard,
not in passive observance, but as a set of dynamic principles
guiding their conduct. It is their duty to practice the profession
according to this code of ethics.
As the keystone of professional conduct is integrity, the members
will discharge their duties with fidelity to the public, their
clients, and with fairness and impartiality to all. They should
uphold the honor and dignity of their profession and avoid
association with any enterprise of questionable character, or
apparent conflict of interest.
- The member will express an opinion only when it is based on
practical experience and honest conviction.
- The member will always act in good faith toward each client.
- The member will not disclose any information concerning the
results of the inspection without the approval of the clients or
their representatives.
- The member will not accept compensation, financial or
otherwise. from more than one interested party for the same
service without the consent of all interested parties.
- The member will not accept nor offer commissions or
allowances, directly or indirectly, from other parties dealing
with their client in connection with work for which the member is
responsible.
- The member will promptly disclose to his client any interest
in a business which may affect the client. The member will not
allow an interest in any business to affect the quality or results
of their inspection work which they may be called upon to perform.
The inspection work may not be used as a vehicle by the inspector
to deliberately obtain work in another field.
- An inspector shall make every effort to uphold, maintain and
improve the professional integrity, reputation and practice of the
home inspection industry. He will report all such relevant
information, including violations of this Code by other members,
to the Association for possible remedial action.